MILLENNIUM TROUBLE-SHOOTING GUIDE
This section lists the messages that may appear on the Millennium’s display, and the probable causes and solutions. If you are unable to solve your problem please call our Customer Service Department for Technical Support.

Displayed Message
Probable Causes/Solutions
Condition...
    In Progress
  • Battery voltage too low to begin charge process.
  • One or more cells shorted.
  • Number of cells set too high.
  • Output leads/alligator clips are shorted.

Battery Not Connected
  • Battery pack connected backwards.
  • Charging attempted with no battery connected.
  • Charging attempted with no power source.
  • Battery pack has open cell or bad connection--Check battery pack and cells.


Battery Not Connected
&
 Press Any Button To Continue
  • Input power source disconnected while charging.
  • Battery disconnected while charging.
  • Battery voltage close to power source voltage–– Increase input power source voltage.
  • Output leads un-shorted during conditioning.


Outputs Shorted
&
 Press Any Button To Continue
  • Output leads un-shorted during conditioning, then re-shorted––Check output leads for short.
  • Output leads shorted during charging––Check output leads for short.


Battery Failure

  • Number of cells set too high.
  • After conditioning, battery voltage still too low to begin charge process––Try new battery.

Charger Shutoff Due To Overheat

  • Internal temperature above 203°F––Check intake grill for blockage. Will go to Start screen when cool.

Set Alarm Tone
-
Ú. . . . . . . . . . +
  • No Alarm or Button tone is heard––Alarm or Button tone is set too low. Increase tone setting.

***To reset all factory defaults and settings, hold down the BACK button during the Millennium’s start-up screen until “Factory Settings Restored” is displayed.