MILLENNIUM
TROUBLE-SHOOTING GUIDE
|
| This section
lists the messages that may appear on the Millennium’s display, and
the probable causes and solutions. If you are unable to solve your
problem please call our Customer Service Department for Technical
Support. |
|
|
Displayed
Message
|
Probable
Causes/Solutions
|
|
|
|
- Battery
voltage too low to begin charge process.
- One
or more cells shorted.
- Number
of cells set too high.
- Output
leads/alligator clips are shorted.
|
|
|
|
- Battery
pack connected backwards.
- Charging
attempted with no battery connected.
- Charging
attempted with no power source.
- Battery
pack has open cell or bad connection--Check battery pack and cells.
|
|
|
Press
Any Button To Continue
|
|
- Input
power source disconnected while charging.
- Battery
disconnected while charging.
- Battery
voltage close to power source voltage–– Increase input power source
voltage.
- Output
leads un-shorted during conditioning.
|
|
|
Press
Any Button To Continue
|
|
- Output
leads un-shorted during conditioning, then re-shorted––Check output
leads for short.
- Output
leads shorted during charging––Check output leads for short.
|
|
|
|
- Number
of cells set too high.
- After
conditioning, battery voltage still too low to begin charge process––Try
new battery.
|
|
|
Charger
Shutoff Due To Overheat
|
|
- Internal
temperature above 203°F––Check intake grill for blockage. Will
go to Start screen when cool.
|
|
|
Set
Alarm Tone
- Ú.
. . . . . . . . . +
|
|
- No
Alarm or Button tone is heard––Alarm or Button tone is set too
low. Increase tone setting.
|
|
| ***To
reset all factory defaults and settings, hold down the BACK button during
the Millennium’s start-up screen until “Factory Settings Restored” is displayed. |