This information can be used to help determine if a motor’s inductance reading is normal and correct for a particular turn motor.
Note: All inductance meters have some variance. It is possible, and very likely, that your meter will read slightly lower or higher than the numbers posted below in the chart. These readings are the low limit. If your motor is reading lower than the results in the chart, you should reinspect your motor further. No single reading should be lower than the numbers in the chart, and all three coils should vary no more than the variance number (The variance number is the maximum difference from the highest reading to the lowest reading). |
|
Please remember to conduct inductance tests with the rotor removed from the motor and from all three combinations of tabs: AB, AC and BC.
Any motors found to be lower can be sent to Novak for confirmation, if needed. Return shipping and handling fees will be charged.
Inductance Chart
|
Variance |
21.5 – 140 µH |
4.5 µH |
17.5 – 90 µH |
3.5 µH |
13.5 – 53 µH |
3 µH |
10.5 – 33 µH |
2 µH |
|
|